Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Yonsei Medical Journal ; : 525-528, 2009.
Article in English | WPRIM | ID: wpr-178610

ABSTRACT

PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Receiver operating characteristic (ROC) curve was constructed for each parameter and the area under the ROC curve (AUC) was calculated. RESULTS: Values of ACA and ACD measured by PTC and AOCT were similar not only in normal open angle eyes but also in occludable angle eyes. For detection of occludable angle, the AUCs of PTC with ACA and ACD were 0.935 and 0.969, respectively. The AUCs of AOCT with ACA and ACD were 0.904 and 0.947, respectively. CONCLUSION: Both PTC and AOCT allow accurate discrimination between open and occludable angle eyes, so that they may aid to screening the occludable angles.


Subject(s)
Aged , Aged, 80 and over , Humans , Middle Aged , Anterior Chamber/anatomy & histology , Tomography, Optical Coherence/methods
2.
Korean Journal of Ophthalmology ; : 1-5, 2009.
Article in English | WPRIM | ID: wpr-15095

ABSTRACT

PURPOSE: To compare the accuracy of central true net corneal power (cTNP) and mean true net corneal power (mTNP) of the Pentacam system to give a keratometry (K) reading for calculating IOL (intraocular lens) power in eyes following refractive surgery. METHODS: Refraction, an automated K-reading (Km), cTNP and mTNP were measured for 15 eyes that required cataract surgery and had previously undergone refractive surgery. The difference between postoperative manifest refraction values and target refraction values calculated with the SRK/T formula using cTNP were compared with the one using mTNP. RESULTS: The mean deviation from the desired post-cataract refractive outcome was 0.60 diopter (D) +/-0.47 (standard deviation) using cTNP; 0.75+/-0.54 using mTNP (p=0.386). The actual refraction was within +/-0.50D of the intended refraction for 60% (cTNP) and 33.3% (mTNP) of eyes, and within +/-1.00D for 93% (cTNP) and 66.7% (mTNP) of eyes. CONCLUSIONS: Although not statistically significant, the cTNP showed better accuracy than mTNP to give a keratometry (K) reading for post-refractive surgery eyes requiring cataract surgery.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Cornea/pathology , Corneal Topography/methods , Lenses, Intraocular , Myopia/surgery , Prosthesis Design , Refraction, Ocular , Refractive Surgical Procedures
3.
Journal of the Korean Ophthalmological Society ; : 1415-1424, 2008.
Article in Korean | WPRIM | ID: wpr-8762

ABSTRACT

PURPOSE: To present a case report of fungal keratitis related to prolonged overnight use of orthokeratology contact lenses. METHODS: A 13 year-old girl presented with a corneal ulcer in her left eye refractory to antibacterial medication. She had a history of wearing orthokeratology contact lenses overnight for seven months. RESULTS: The organism Aspergillus was isolated by corneal scraping, the contact lens itself, and from the storage case. The patient was treated with topical fluconazole and Natamycin pimaricin in addition to oral itraconazole, resulting in a resolution of the ocular lesion. CONCLUSIONS: The risk of fungal infection as a potential complication of the use of overnight orthkeratology contact lenses should be considered when using these lenses.


Subject(s)
Humans , Aspergillus , Contact Lenses , Corneal Dystrophies, Hereditary , Corneal Ulcer , Eye , Fluconazole , Itraconazole , Keratitis , Keratomileusis, Laser In Situ , Natamycin
4.
Korean Journal of Ophthalmology ; : 242-245, 2008.
Article in English | WPRIM | ID: wpr-150870

ABSTRACT

PURPOSE: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. METHODS: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated. RESULTS: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p>0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all >0.9). CONCLUSIONS: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACD.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Anterior Chamber/anatomy & histology , Anterior Eye Segment , Cross-Sectional Studies , Diagnostic Techniques, Ophthalmological , Observer Variation , Photography/methods , Prospective Studies , Reproducibility of Results , Tomography, Optical Coherence/methods , Trabecular Meshwork/anatomy & histology
SELECTION OF CITATIONS
SEARCH DETAIL